A biomechanical confirmation of the relationship between critical shoulder angle (CSA) and articular joint loading

Eline van Der Kruk
  • Fonction : Auteur
Asim Bhuta
  • Fonction : Auteur
Matthias Zumstein
  • Fonction : Auteur
Beat Moor
  • Fonction : Auteur
Roger J.H. Emery
  • Fonction : Auteur
Anthony M.J. Bull
  • Fonction : Auteur
Peter Reilly
  • Fonction : Auteur

Résumé

BackgroundThe critical shoulder angle (CSA) has been shown to be correlated with shoulder disease states. The biomechanical hypothesis to explain this correlation is that the CSA changes the shear and compressive forces on the shoulder. The objective of this study is to test this hypothesis by use of a validated computational shoulder model. Specifically, this study assesses the impact on glenohumeral biomechanics of modifying the CSA.MethodsAn inverse dynamics 3-dimensional musculoskeletal model of the shoulder was used to quantify muscle forces and glenohumeral joint forces. The CSA was changed by altering the attachment point of the middle deltoid into a normal CSA (33°), a reduced CSA of 28°, and an increased CSA of 38°. Subject-specific kinematics of slow and fast speed abduction in the scapular plane and slow and fast forward flexion measured by a 3-dimensional motion capture system were used to quantify joint reaction shear and compressive forces.ResultsIncreasing the CSA results in increased superior-inferior forces (shearing forces; integrated over the range of motion; P < .05). Reducing CSA results in increased lateromedial (compressive) forces for both the maximum and integrated sum of the forces over the whole motion (P < .01).Discussion/ConclusionChanges in the CSA modify glenohumeral joint biomechanics with increasing CSA producing higher shear forces that could contribute to rotator cuff overuse, whereas reducing the CSA results in higher compressive forces that contribute to joint wear.
Fichier principal
Vignette du fichier
S1058274620302408.pdf (548.39 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03138748 , version 1 (21-09-2022)

Licence

Identifiants

Citer

Guillaume Villatte, Eline van Der Kruk, Asim Bhuta, Matthias Zumstein, Beat Moor, et al.. A biomechanical confirmation of the relationship between critical shoulder angle (CSA) and articular joint loading. Journal of Shoulder and Elbow Surgery, 2020, 29 (10), pp.1967-1973. ⟨10.1016/j.jse.2020.03.002⟩. ⟨hal-03138748⟩
53 Consultations
74 Téléchargements

Altmetric

Partager

More